๐ฉปImage placeholder
Radiology ยท Imaging
SonoSite Portable Ultrasound
Point-of-care portable ultrasound system for bedside imaging and procedural guidance.
AI overview
Compact, battery-capable ultrasound platform used across the OR, ICU, ED, and bedside for diagnostic imaging, vascular access, and procedural guidance with interchangeable transducers.
Ask Skantra about thisCommon uses
- Vascular access (central / peripheral line placement)
- FAST exam in trauma assessment
- Cardiac and lung point-of-care ultrasound
- Procedural guidance (paracentesis, thoracentesis, nerve blocks)
Safety notes
- Use only hospital-approved disinfectants compatible with each probe type
- Do not immerse connectors; follow probe-specific reprocessing guidance
- Avoid excessive probe pressure on fragile tissue or recent surgical sites
Setup instructions
- 1Initial inspection โ verify the machine is clean and free from visible damage.
- 2Initial inspection โ inspect power cord, battery, probes, and cables for wear or defects.
- 3Initial inspection โ confirm the correct ultrasound probe is available for the procedure.
- 4Position the machine โ move the ultrasound system to the desired patient care area.
- 5Position the machine โ lock wheel brakes if equipped.
- 6Position the machine โ ensure adequate space for operator access and cable movement.
- 7Power on the system โ plug the machine into a grounded electrical outlet or verify battery charge.
- 8Power on the system โ press the power button to start the system.
- 9Power on the system โ allow the system to complete startup diagnostics.
- 10Connect the probe โ select the appropriate transducer/probe for the exam type.
- 11Connect the probe โ align the connector properly and securely attach it to the machine port.
- 12Connect the probe โ confirm probe recognition on the display screen.
- 13Prepare the patient โ position the patient appropriately for the exam or procedure.
- 14Prepare the patient โ expose the required anatomical area.
- 15Prepare the patient โ apply ultrasound gel to the probe or patient skin.
- 16Configure imaging settings โ select the desired exam preset (cardiac, vascular, abdominal, etc.).
- 17Configure imaging settings โ adjust depth, gain, and image settings as needed.
- 18Configure imaging settings โ confirm image quality before beginning the procedure.
- 19Perform the scan or procedure โ place the probe gently on the patient.
- 20Perform the scan or procedure โ adjust probe angle and pressure for optimal imaging.
- 21Perform the scan or procedure โ save images or clips if documentation is required.
- 22Post-procedure cleanup โ remove ultrasound gel from patient and probe.
- 23Post-procedure cleanup โ disconnect and disinfect probes according to facility policy.
- 24Post-procedure cleanup โ clean touch surfaces and machine components.
- 25Post-procedure cleanup โ return the machine to charging if battery-operated.
Troubleshooting
Probe not recognized
Reseat the transducer connector and confirm it's fully latched; try another port or probe to isolate.
Poor image quality
Reapply gel, adjust depth/gain, and verify the correct exam preset and probe for the application.
Won't power on
Confirm AC power at outlet, check battery charge, and try powering on with AC connected.
Training video
My notes